whiteSKY T.L. & A.L. – Conventional or Digital

Share:

Conventional or Digital - The choice is yours!

The whiteSKY implant system has proven itself clinically and scientifically since its introduction in 2006. The two new improved designs retain all the beneficial features of the first generation whiteSKY – Reshaping clinical and scientific success. Choose between concave and tulip.

Proven manufacturing process and successful clinical therapy

With whiteSKY Tissue Line and Alveo Line, the intricate manufacturing process from Hot Isostatic Pressed (HIP) zirconia and the proven surface treatment remain unchanged.
The one-piece design has also been retained to avoid the development of micro-gaps. This guarantees the long-term survival of the implant. The optimized design and the bone-oriented surgical protocol of the whiteSKY implants achieve excellent primary stability, which is a prerequisite for
immediate restoration and also highly recommended as clinical research indicates that immediate restoration can increase bone-implant-contact (BIC) by 50%.

Histology of a whiteSKY implant
Source : Stadlinger et al, IJOMS 2010

Muco-integration of the whiteSKY Alveo Line 6 months post-op.
Source: Prof. A. Borgonovo, Milan, Italy

Excellent clinical and scientific results

The first generation whiteSKY implant is one of the best documented zirconia implant systems. Clinical and scientific examinations were carried out from the very beginning.
Histologic examinations confirmed the good osseointegration of the implants. These results were also confirmed clinically. The long-term survival rate is on par with titanium implants. The bone level is stable in the long-term and the red-white aesthetics is superb. The second generation whiteSKY retains the proven success factors and introduces improvements requested by the customers. Prof. Andrea Borgonovo et al. evaluated the 10-year success rate of 26 one-piece whiteSKY zirconia implants of the first generation. The success rate was 100%
with an average marginal bone loss (MBL) of less than 1 mm, an average periodontal probing
depth (PPD) of 3 mm with no bleeding on probing (BOP). In a few cases, there was a slight bone gain less than 1mm. Compared with titanium implants, the whiteSKY zirconia implant achieves similar or even better long-term results.

Two profiles - the choice is yours

Be it the concave or tulip shape in the sulcus region – both offer optimal conditions
for the attachment of soft tissue due to the tissue-friendly surface in this area. This improves
the aesthetics and ensures long-term success. The one-piece whiteSKY Tissue Line is the slim, elegant implant that offers plenty of space for hard and soft tissue and usually does not need customization. Intra-oral scan can be easily carried out in digital workflow.
Impression taking is also easily carried out in conventional workflow. Standardised procedure
in the dental practice makes everything quick and easy.

The one-piece whiteSKY Alveo Line gives you the possibility to fill the alveolus during immediate implant placement and individualise the implant depending on the requirements of the clinical case. In this case you can handle the implant like a natural tooth
during impression taking and prosthetic restoration.

Improved prosthetic superstructure

The improved prosthetic superstructure facilitates the integration of completely metalfree restorations with zirconia, lithium disilicate or composite. There are no restrictions in the choice of materials and indications.

For more information: www.bredent-implants.com

Press Contact

Ms. Koch Silvia

+49 7309 872-610

stay tuned

Subscribe to our bredent group Press Mailing List

* required fields

Thank you for registering!